apply: instrument , electrial fixture , testing fixture
Standard Interface System (SIS) - Provides reliable and fast physical connection solutions for equipment, instruments, fixtures, and test systems.
Standard Interface Module (SIM) - Provides flexible modular configuration for the pylon interface .
Standard Interface Frame (SIF) - Designs suitable frame structures for different systems and application scenarios.
High Current Module:
Fixture side PN: AI-F-P20
Base station side PN: AI-B-P20
Features:
• 20 Pin large current module
• Maximum current per probe: 30A
• Recommended standard working current: 20A
• Typical value of spring probe resistance (Ri): <10 mOhm
• Double-sided screen print, standard numbering, convenient for debugging and wiring maintenance.
Mixed Module for signal and air :
Fixture side PN: AI-F-P66-1Air6
Base station side PN: AI-B-P66-1Air6
Features:
• Single-channel pneumatic mixed module
• Maximum current per probe: 4A
• Typical value of probe resistance (Ri): <20 mOhm
• 24V DC power supply (power supply for internal modules and components of the fixture)
• Probe connection used for I/O signal transmission, switch control, and pneumatic control
• Self-locking function of the air nozzle, no leakage when plugging and unplugging
• Double-sided screen print , standard numbering, convenient for debugging and wiring maintenance.
Mixed Module for signal and air :
Fixture side PN: AI-C-F-P66-Air
Base station side PN: AI-C-B-P66-Air
Features:
• Single-channel pneumatic mixed module
• Maximum current per probe: 4A
• Typical value of probe resistance (Ri): <20 mOhm
• 24V DC power supply (power supply for internal modules and components of the fixture)
• Probe connection used for I/O signal transmission, switch control, and pneumatic control
• Self-locking function of the air nozzle, no leakage when plugging and unplugging
• Double-sided screen print , standard numbering, convenient for debugging and wiring maintenance.
* 3 flexiable pneumatic air connection
Pneumatic Module:
Fixture side PN: AI-F-P66-2Air4
Base station side PN: AI-B-P66-2Air4
Features:
• Dual-channel pneumatic module
• Can be used for all test fixtures with internal or external Pylon interfaces
• Constant low transition loss
• High probe reliability and transmission quality
• Self-locking function of the air nozzle, no leakage when plugging and unplugging.
Signal Module:
Fixture side PN: AI-F-P170
Base station side PN: AI-B-P170
Features:
• Maximum current per probe: 4A
• Typical value of spring probe resistance (Ri): <20 mOhm
• 170 channel connection (power supply for internal modules and components of the fixture)
• Can be used for I/O signal transmission and switch control
• Double-sided silk screen, standard numbering, convenient for debugging and wiring maintenance.
Signal Module:
Fixture side PN: CIPOS-F-P45
Base station side PN: CIPOS-B-P45
Features:
• Maximum current per probe: 4A
• Typical value of spring probe resistance (Ri): <20 mOhm
• 45 channel connection (power supply for internal modules and components of the fixture)
• Can be used for I/O signal transmission and switch control
• Double-sided silk screen, standard numbering, convenient for debugging and wiring maintenance.
• Customize pylon modules
Signal Module:
Fixture side PN: CIPOS-F-P170
Base station side PN: CIPOS-B-P170
Features:
• Maximum current per probe: 4A
• Typical value of spring probe resistance (Ri): <20 mOhm
• 170 channel connection (power supply for internal modules and components of the fixture)
• Can be used for I/O signal transmission and switch control
• Double-sided silk screen, standard numbering, convenient for debugging and wiring maintenance.
• Customize pylon modules
Signal Module:
Fixture side PN: MI-F-P170
Base station side PN: MI-B-P170
Features:
• Maximum current per probe: 5A
• Typical value of spring probe resistance (Ri): <20 mOhm
• 170 channel connection (power supply for internal modules and components of the fixture)
• Can be used for I/O signal transmission and switch control
• Double-sided silk screen, standard numbering, convenient for debugging and wiring maintenance.
• apply in manual test station
Support:INFOO|Record number:沪ICP备2022012804号-1